<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0">
  <channel>
    <title>지진</title>
    <link>https://bmtars.tistory.com/</link>
    <description></description>
    <language>ko</language>
    <pubDate>Thu, 13 Aug 2026 20:46:21 +0900</pubDate>
    <generator>TISTORY</generator>
    <ttl>100</ttl>
    <managingEditor>BMTARS</managingEditor>
    <image>
      <title>지진</title>
      <url>https://t1.daumcdn.net/cfile/tistory/2221BE345801B0B40C</url>
      <link>https://bmtars.tistory.com</link>
    </image>
    <item>
      <title>클레임 연구소#4. 비구조요소 내진설계 3탄: 기계/전기 설비의 내진 (2026 개정 핵심) [유투브 영상]</title>
      <link>https://bmtars.tistory.com/324</link>
      <description>&lt;p data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;color: #000000;&quot;&gt;유투브&amp;nbsp;채널『클레임&amp;nbsp;연구소』를&amp;nbsp;운영하시는&amp;nbsp;건축구조기술사께서&amp;nbsp;제작&amp;middot;공개한&amp;nbsp;「비구조요소&amp;nbsp;내진설계」관련&amp;nbsp;유투브&amp;nbsp;영상#3을&amp;nbsp;공유합니다.&amp;nbsp;&lt;/span&gt;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&lt;a href=&quot;https://youtu.be/Qg046clgybU?si=qbBEgOQUu_Qn5CF4&quot; target=&quot;_blank&quot; rel=&quot;noopener&amp;nbsp;noreferrer&quot;&gt;[건축구조] 비구조요소 내진설계 3탄: 기계/전기 설비의 내진 (2026 개정 핵심)&lt;/a&gt;&lt;/p&gt;
&lt;figure data-ke-type=&quot;video&quot; data-ke-style=&quot;alignCenter&quot; data-video-host=&quot;youtube&quot; data-video-url=&quot;https://www.youtube.com/watch?v=Qg046clgybU&quot; data-video-thumbnail=&quot;https://scrap.kakaocdn.net/dn/kk2cU/dJMb9fZGiW0/Tzqo9HHINk3KAtB0IQKfmK/img.jpg?width=1280&amp;amp;height=720&amp;amp;face=0_0_1280_720,https://scrap.kakaocdn.net/dn/boKFof/dJMb8YXWP3j/FuzvKZ3t47KfMPGIhfZlEk/img.jpg?width=1280&amp;amp;height=720&amp;amp;face=0_0_1280_720,https://scrap.kakaocdn.net/dn/eh4U0h/dJMb8RR21wW/vYktEzg0cYOkmLJQa1UkDK/img.jpg?width=1280&amp;amp;height=720&amp;amp;face=0_0_1280_720&quot; data-video-width=&quot;860&quot; data-video-height=&quot;484&quot; data-video-origin-width=&quot;860&quot; data-video-origin-height=&quot;484&quot; data-ke-mobilestyle=&quot;widthContent&quot; data-video-title=&quot;[건축구조] 비구조요소 내진설계 3탄: 기계/전기 설비의 내진 (2026 개정 핵심)&quot; data-original-url=&quot;&quot;&gt;&lt;iframe src=&quot;https://www.youtube.com/embed/Qg046clgybU&quot; width=&quot;860&quot; height=&quot;484&quot; frameborder=&quot;&quot; allowfullscreen=&quot;true&quot;&gt;&lt;/iframe&gt;
&lt;figcaption&gt;[ 출처 : 클레임 연구소 - YouTube ]&lt;/figcaption&gt;
&lt;/figure&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;figure class=&quot;imageblock alignCenter&quot; data-ke-mobileStyle=&quot;widthOrigin&quot; data-filename=&quot;260627.png&quot; data-origin-width=&quot;400&quot; data-origin-height=&quot;400&quot;&gt;&lt;a href=&quot;https://www.youtube.com/@%ED%81%B4%EB%A0%88%EC%9E%84&quot; target=&quot;_blank&quot; title=&quot;클레임연구소&quot;&gt;&lt;img src=&quot;https://blog.kakaocdn.net/dn/dqgK3A/dJMb99NFCrC/cd2aEETSJcrRtJ0ko1RPVk/img.png&quot; srcset=&quot;https://img1.daumcdn.net/thumb/R1280x0/?scode=mtistory2&amp;fname=https%3A%2F%2Fblog.kakaocdn.net%2Fdn%2FdqgK3A%2FdJMb99NFCrC%2Fcd2aEETSJcrRtJ0ko1RPVk%2Fimg.png&quot; onerror=&quot;this.onerror=null; this.src='//t1.daumcdn.net/tistory_admin/static/images/no-image-v1.png'; this.srcset='//t1.daumcdn.net/tistory_admin/static/images/no-image-v1.png';&quot; loading=&quot;lazy&quot; width=&quot;400&quot; height=&quot;400&quot; data-filename=&quot;260627.png&quot; data-origin-width=&quot;400&quot; data-origin-height=&quot;400&quot;/&gt;&lt;/a&gt;&lt;/figure&gt;
&lt;/p&gt;</description>
      <category>구조상식</category>
      <category>건축구조기술사</category>
      <category>비구조요소</category>
      <category>비구조요소내진설계</category>
      <category>클레임연구소</category>
      <author>BMTARS</author>
      <guid isPermaLink="true">https://bmtars.tistory.com/324</guid>
      <comments>https://bmtars.tistory.com/324#entry324comment</comments>
      <pubDate>Fri, 3 Jul 2026 00:25:44 +0900</pubDate>
    </item>
    <item>
      <title>클레임 연구소#3. 비구조요소 내진설계 2탄: 건축 비구조요소의 정석 [유투브 영상]</title>
      <link>https://bmtars.tistory.com/323</link>
      <description>&lt;p data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;color: #000000; text-align: start;&quot;&gt;유투브 채널『클레임 연구소』를 운영하시는 건축구조기술사께서 제작&amp;middot;공개한 「비구조요소 내진설계」관련 유투브 영상#2를 공유합니다.&amp;nbsp;&lt;/span&gt;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;color: #000000; text-align: start;&quot;&gt;&lt;a href=&quot;https://youtu.be/BNeYNb9KxCg?si=1CvLUJ-Z3zlanKAC&quot; target=&quot;_blank&quot; rel=&quot;noopener&amp;nbsp;noreferrer&quot;&gt;[건축구조] 비구조요소 내진설계 2탄: 건축 비구조요소의 정석&lt;/a&gt;&lt;/span&gt;&lt;/p&gt;
&lt;figure data-ke-type=&quot;video&quot; data-ke-style=&quot;alignCenter&quot; data-video-host=&quot;youtube&quot; data-video-url=&quot;https://www.youtube.com/watch?v=BNeYNb9KxCg&quot; data-video-thumbnail=&quot;https://scrap.kakaocdn.net/dn/cKBeE4/dJMb887jPOW/Zyk3kjYEZPImOZkMzUDMqK/img.jpg?width=1280&amp;amp;height=720&amp;amp;face=0_0_1280_720,https://scrap.kakaocdn.net/dn/jgnog/dJMb89yoGMw/z9kbtkFyBvshGWXkBVRV6K/img.jpg?width=1280&amp;amp;height=720&amp;amp;face=0_0_1280_720,https://scrap.kakaocdn.net/dn/ela0AR/dJMb89yoGMx/AKpbYGZkXjEtbjH5X49EM1/img.jpg?width=1280&amp;amp;height=720&amp;amp;face=0_0_1280_720&quot; data-video-width=&quot;860&quot; data-video-height=&quot;484&quot; data-video-origin-width=&quot;860&quot; data-video-origin-height=&quot;484&quot; data-ke-mobilestyle=&quot;widthContent&quot; data-video-title=&quot;[건축구조] 비구조요소 내진설계 2탄: 건축 비구조요소의 정석&quot; data-original-url=&quot;&quot;&gt;&lt;iframe src=&quot;https://www.youtube.com/embed/BNeYNb9KxCg&quot; width=&quot;860&quot; height=&quot;484&quot; frameborder=&quot;&quot; allowfullscreen=&quot;true&quot;&gt;&lt;/iframe&gt;
&lt;figcaption&gt;[ 출처 : 클레임 연구소 - YouTube ]&lt;/figcaption&gt;
&lt;/figure&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;figure class=&quot;imageblock alignCenter&quot; data-ke-mobileStyle=&quot;widthOrigin&quot; data-filename=&quot;260627.png&quot; data-origin-width=&quot;400&quot; data-origin-height=&quot;400&quot;&gt;&lt;a href=&quot;https://www.youtube.com/@%ED%81%B4%EB%A0%88%EC%9E%84&quot; target=&quot;_blank&quot; title=&quot;클레임연구소&quot;&gt;&lt;img src=&quot;https://blog.kakaocdn.net/dn/bKSNwI/dJMcaftDhF0/CIl3OXQ2lB76PTquHlfkJk/img.png&quot; srcset=&quot;https://img1.daumcdn.net/thumb/R1280x0/?scode=mtistory2&amp;fname=https%3A%2F%2Fblog.kakaocdn.net%2Fdn%2FbKSNwI%2FdJMcaftDhF0%2FCIl3OXQ2lB76PTquHlfkJk%2Fimg.png&quot; onerror=&quot;this.onerror=null; this.src='//t1.daumcdn.net/tistory_admin/static/images/no-image-v1.png'; this.srcset='//t1.daumcdn.net/tistory_admin/static/images/no-image-v1.png';&quot; loading=&quot;lazy&quot; width=&quot;400&quot; height=&quot;400&quot; data-filename=&quot;260627.png&quot; data-origin-width=&quot;400&quot; data-origin-height=&quot;400&quot;/&gt;&lt;/a&gt;&lt;/figure&gt;
&lt;/p&gt;</description>
      <category>구조상식</category>
      <category>건축구조기술사</category>
      <category>비구조요소</category>
      <category>비구조요소내진설계</category>
      <category>틀레임연구소</category>
      <author>BMTARS</author>
      <guid isPermaLink="true">https://bmtars.tistory.com/323</guid>
      <comments>https://bmtars.tistory.com/323#entry323comment</comments>
      <pubDate>Fri, 3 Jul 2026 00:22:02 +0900</pubDate>
    </item>
    <item>
      <title>클레임 연구소#2. 비구조요소 내진설계 제1탄-기초 개념 및 행정실무 가이드 [유투브 영상]</title>
      <link>https://bmtars.tistory.com/322</link>
      <description>&lt;p data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;color: #000000; text-align: start;&quot;&gt;유투브 채널『클레임 연구소』를 운영하시는 건축구조기술사께서 제작&amp;middot;공개한 「비구조요소 내진설계」관련 유투브 영상#1을 공유합니다.&amp;nbsp;&lt;/span&gt;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&lt;a href=&quot;https://www.youtube.com/watch?v=vpMaNpHjuPE&amp;amp;list=PLP_D7g7xeyrRkvnzEYTvxX-LOEeflOyzQ&amp;amp;index=2&quot;&gt;[건축구조] 비구조요소 내진설계 제1탄-기초 개념 및 행정실무 가이드&lt;/a&gt;&lt;/p&gt;
&lt;figure data-ke-type=&quot;video&quot; data-ke-style=&quot;alignCenter&quot; data-video-host=&quot;youtube&quot; data-video-url=&quot;https://www.youtube.com/watch?v=vpMaNpHjuPE&amp;amp;list=PLP_D7g7xeyrRkvnzEYTvxX-LOEeflOyzQ&amp;amp;index=2&quot; data-video-thumbnail=&quot;https://scrap.kakaocdn.net/dn/bhevqJ/dJMb887i5rT/YbH2geMpQCrn6uJuq3hDPK/img.jpg?width=1280&amp;amp;height=720&amp;amp;face=0_0_1280_720,https://scrap.kakaocdn.net/dn/bjoigc/dJMb83Stkfm/EBzGo3coBgfkYJwLftyaxK/img.jpg?width=1280&amp;amp;height=720&amp;amp;face=0_0_1280_720,https://scrap.kakaocdn.net/dn/bFKKq8/dJMb81G7NTd/exDh0Fwky0ND5FNr61S5Kk/img.jpg?width=1280&amp;amp;height=720&amp;amp;face=0_0_1280_720&quot; data-video-width=&quot;860&quot; data-video-height=&quot;484&quot; data-video-origin-width=&quot;860&quot; data-video-origin-height=&quot;484&quot; data-ke-mobilestyle=&quot;widthContent&quot; data-video-title=&quot;[건축구조] 비구조요소 내진설계 제1탄-기초 개념 및 행정실무 가이드&quot; data-original-url=&quot;&quot;&gt;&lt;iframe src=&quot;https://www.youtube.com/embed/vpMaNpHjuPE&quot; width=&quot;860&quot; height=&quot;484&quot; frameborder=&quot;&quot; allowfullscreen=&quot;true&quot;&gt;&lt;/iframe&gt;
&lt;figcaption&gt;[ 출처 : 클레임 연구소 - YouTube ]&lt;/figcaption&gt;
&lt;/figure&gt;
&lt;p&gt;&lt;figure class=&quot;imageblock alignCenter&quot; data-ke-mobileStyle=&quot;widthOrigin&quot; data-filename=&quot;260627.png&quot; data-origin-width=&quot;400&quot; data-origin-height=&quot;400&quot;&gt;&lt;a href=&quot;https://www.youtube.com/@%ED%81%B4%EB%A0%88%EC%9E%84&quot; target=&quot;_blank&quot; title=&quot;유투브 &amp;quot;클레임 연구소&amp;quot; 채널&quot;&gt;&lt;img src=&quot;https://blog.kakaocdn.net/dn/p0128/dJMcabdzR4A/Gt5ukkY10CcCXYMaTb4GfK/img.png&quot; srcset=&quot;https://img1.daumcdn.net/thumb/R1280x0/?scode=mtistory2&amp;fname=https%3A%2F%2Fblog.kakaocdn.net%2Fdn%2Fp0128%2FdJMcabdzR4A%2FGt5ukkY10CcCXYMaTb4GfK%2Fimg.png&quot; onerror=&quot;this.onerror=null; this.src='//t1.daumcdn.net/tistory_admin/static/images/no-image-v1.png'; this.srcset='//t1.daumcdn.net/tistory_admin/static/images/no-image-v1.png';&quot; loading=&quot;lazy&quot; width=&quot;400&quot; height=&quot;400&quot; data-filename=&quot;260627.png&quot; data-origin-width=&quot;400&quot; data-origin-height=&quot;400&quot;/&gt;&lt;/a&gt;&lt;/figure&gt;
&lt;/p&gt;</description>
      <category>구조상식</category>
      <category>건축구조기술사</category>
      <category>비구조요소</category>
      <category>비구조요소내진설계</category>
      <category>클레임연구소</category>
      <author>BMTARS</author>
      <guid isPermaLink="true">https://bmtars.tistory.com/322</guid>
      <comments>https://bmtars.tistory.com/322#entry322comment</comments>
      <pubDate>Sat, 27 Jun 2026 02:15:31 +0900</pubDate>
    </item>
    <item>
      <title>클레임 연구소#1. 비구조요소 내진설계, 현장의 책임이 되다 [유투브 영상]</title>
      <link>https://bmtars.tistory.com/321</link>
      <description>&lt;p data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;color: #000000;&quot;&gt;유투브 채널『클레임 연구소』를 운영하시는 건축구조기술사께서 제작&amp;middot;공개한 「비구조요소 내진설계」관련 유투브 영상#1을 공유합니다.&amp;nbsp;&lt;/span&gt;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&lt;a href=&quot;https://www.youtube.com/watch?v=2NDQEY2A1wo&amp;amp;list=PLP_D7g7xeyrRkvnzEYTvxX-LOEeflOyzQ&quot;&gt;[건축구조] 티저영상-비구조요소 내진설계 안내서 2026년판&lt;/a&gt;&lt;/p&gt;
&lt;figure data-ke-type=&quot;video&quot; data-ke-style=&quot;alignCenter&quot; data-video-host=&quot;youtube&quot; data-video-url=&quot;https://www.youtube.com/watch?v=2NDQEY2A1wo&amp;amp;list=PLP_D7g7xeyrRkvnzEYTvxX-LOEeflOyzQ&quot; data-video-thumbnail=&quot;https://scrap.kakaocdn.net/dn/foKbb/dJMb83Stkc4/lTjj0usUywDXeFXZo9mo6k/img.jpg?width=1280&amp;amp;height=720&amp;amp;face=0_0_1280_720,https://scrap.kakaocdn.net/dn/STaJC/dJMb89ynWsK/gemXqLJmSnc3yk49XCCb3k/img.jpg?width=1280&amp;amp;height=720&amp;amp;face=0_0_1280_720,https://scrap.kakaocdn.net/dn/jJr57/dJMb86n7WVd/7x7yqU7TKkzUo8n6c6qxp0/img.jpg?width=1280&amp;amp;height=720&amp;amp;face=0_0_1280_720&quot; data-video-width=&quot;860&quot; data-video-height=&quot;484&quot; data-video-origin-width=&quot;860&quot; data-video-origin-height=&quot;484&quot; data-ke-mobilestyle=&quot;widthContent&quot; data-video-title=&quot;[건축구조] 티저영상-비구조요소 내진설계 안내서 2026년판&quot; data-original-url=&quot;&quot;&gt;&lt;iframe src=&quot;https://www.youtube.com/embed/2NDQEY2A1wo&quot; width=&quot;860&quot; height=&quot;484&quot; frameborder=&quot;&quot; allowfullscreen=&quot;true&quot;&gt;&lt;/iframe&gt;
&lt;figcaption&gt;[ 출처 : 클레임 연구소 - YouTube ]&lt;/figcaption&gt;
&lt;/figure&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;figure class=&quot;imageblock alignCenter&quot; data-ke-mobileStyle=&quot;widthOrigin&quot; data-filename=&quot;260627.png&quot; data-origin-width=&quot;400&quot; data-origin-height=&quot;400&quot;&gt;&lt;a href=&quot;https://www.youtube.com/@%ED%81%B4%EB%A0%88%EC%9E%84&quot; target=&quot;_blank&quot; title=&quot;유투브 &amp;quot;클레임 연구소&amp;quot; 채널&quot;&gt;&lt;img src=&quot;https://blog.kakaocdn.net/dn/dy8Nll/dJMcaaFRLQQ/FWgOodyk2W2I4WqhgUkOX1/img.png&quot; srcset=&quot;https://img1.daumcdn.net/thumb/R1280x0/?scode=mtistory2&amp;fname=https%3A%2F%2Fblog.kakaocdn.net%2Fdn%2Fdy8Nll%2FdJMcaaFRLQQ%2FFWgOodyk2W2I4WqhgUkOX1%2Fimg.png&quot; onerror=&quot;this.onerror=null; this.src='//t1.daumcdn.net/tistory_admin/static/images/no-image-v1.png'; this.srcset='//t1.daumcdn.net/tistory_admin/static/images/no-image-v1.png';&quot; loading=&quot;lazy&quot; width=&quot;400&quot; height=&quot;400&quot; data-filename=&quot;260627.png&quot; data-origin-width=&quot;400&quot; data-origin-height=&quot;400&quot;/&gt;&lt;/a&gt;&lt;/figure&gt;
&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;</description>
      <category>구조상식</category>
      <category>건축구조기술사</category>
      <category>비구조요소</category>
      <category>비구조요소내진설계</category>
      <category>클레임연구소</category>
      <author>BMTARS</author>
      <guid isPermaLink="true">https://bmtars.tistory.com/321</guid>
      <comments>https://bmtars.tistory.com/321#entry321comment</comments>
      <pubDate>Sat, 27 Jun 2026 02:11:26 +0900</pubDate>
    </item>
    <item>
      <title>[무료책자.2026년판]시공자 및 감리자를 위한 비구조요소 내진설계안내서 2026년판</title>
      <link>https://bmtars.tistory.com/316</link>
      <description>&lt;p style=&quot;color: #333333; text-align: start;&quot; data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;font-family: 'Noto Serif KR'; color: #000000;&quot;&gt;이 안내서는 비구조요소 및 건물외구조물에 대한 시공자와 감리자의 이해도를 높이고, 실무파악 및 업무처리에 도움이 되길 바라는 마음으로 작성하였습니다. &lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;color: #333333; text-align: start;&quot; data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;font-family: 'Noto Serif KR'; color: #000000;&quot;&gt;2023년, 2024년, 2025년에 이어서 2026년판을 만들어 배포합니다.&amp;nbsp;&lt;/span&gt;&lt;span style=&quot;color: #000000; font-family: 'Noto Serif KR';&quot;&gt;2026년판에서는 10개 주제를 새롭게 추가하여 총 103개 주제를 담았습니다. &lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;color: #333333; text-align: start;&quot; data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;color: #000000; font-family: 'Noto Serif KR';&quot;&gt;2026년판의 특징은 크게 세가지 입니다. &lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;color: #333333; text-align: start;&quot; data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;color: #000000; font-family: 'Noto Serif KR';&quot;&gt;첫째는 내진특등급에서 기능수행에 대한 내용입니다. &lt;/span&gt;&lt;span style=&quot;color: #000000; font-family: 'Noto Serif KR';&quot;&gt;내진특등급 건축물에서 비구조요소 내진설계&amp;middot;검토 대상이 되는 비구조요소 범위는 &amp;lsquo;인명안전&amp;rsquo;과 관련해서는 고민의 여지가 없지만, &amp;lsquo;기능수행&amp;rsquo;과 관련해서는 건축주&amp;middot;시공자&amp;middot;감리자에게 깊은 고민&amp;middot;판단이 요구됩니다. 이에 대해서 공사관계자가 합리적인 결정에 도달할 수 있도록 이번 추가 주제에 포함하였습니다. &lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;color: #333333; text-align: start;&quot; data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;color: #000000; font-family: 'Noto Serif KR';&quot;&gt;둘째는 &lt;span style=&quot;font-family: 'Noto Serif KR'; color: #000000; text-align: start;&quot;&gt;전기 및 기계 비구조요소에 대한 내용입니다. &lt;/span&gt;그동안 설명이 미흡했던 전기 및 기계 비구조요소와 관련한 내진설계 기준이 &amp;lsquo;26년 2월 23일자에 제정됨에 따라 내진설계 대상을 정하는 방법도 구체적으로 정리하였습니다. &lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;color: #333333; text-align: start;&quot; data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;color: #000000; font-family: 'Noto Serif KR';&quot;&gt;셋째는 위의 두 가지에 대해 구체화시키면서 이와 관련된 내용과 그 외의 내용에 대해서도 기존의 설명이 애매하거나 오해의 여지가 있는 부분을 보다 구체적으로 보완하고 수정하였습니다.&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;color: #333333; text-align: start;&quot; data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;font-family: 'Noto Serif KR'; color: #000000;&quot;&gt;2026년판을 공개하면서 기존의 안내서에 대한 다운로드는 차단합니다.&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;text-align: center;&quot; data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&amp;nbsp;&lt;br /&gt;&lt;span style=&quot;color: #666666;&quot;&gt;&lt;i&gt;[아래&amp;nbsp;첨부파일을&amp;nbsp;클릭하여&amp;nbsp;다운받을&amp;nbsp;수&amp;nbsp;있습니다]&lt;/i&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p&gt;&lt;figure class=&quot;fileblock&quot; data-ke-align=&quot;alignCenter&quot;&gt;&lt;a href=&quot;https://blog.kakaocdn.net/dn/bKPOEI/dJMcahR2mj0/g6fdI6FNOyis3KxbwUkZFK/%5Bebook.2026%EB%85%84%ED%8C%90%5D%EC%8B%9C%EA%B3%B5%EC%9E%90%EB%B0%8F%EA%B0%90%EB%A6%AC%EC%9E%90%EB%A5%BC%EC%9C%84%ED%95%9C%EB%B9%84%EA%B5%AC%EC%A1%B0%EC%9A%94%EC%86%8C%EB%82%B4%EC%A7%84%EC%84%A4%EA%B3%84%EC%95%88%EB%82%B4%EC%84%9C2026%EB%85%84%ED%8C%90.pdf?attach=1&amp;amp;knm=tfile.pdf&quot; class=&quot;&quot;&gt;
    &lt;div class=&quot;image&quot;&gt;&lt;/div&gt;
    &lt;div class=&quot;desc&quot;&gt;&lt;div class=&quot;filename&quot;&gt;&lt;span class=&quot;name&quot;&gt;[ebook.2026년판]시공자및감리자를위한비구조요소내진설계안내서2026년판.pdf&lt;/span&gt;&lt;/div&gt;
&lt;div class=&quot;size&quot;&gt;6.84MB&lt;/div&gt;
&lt;/div&gt;
  &lt;/a&gt;&lt;/figure&gt;
&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p&gt;&lt;figure class=&quot;imageblock alignCenter&quot; data-ke-mobileStyle=&quot;widthOrigin&quot; data-filename=&quot;비구조요소내진설계안내서(2026년판)표제지.png&quot; data-origin-width=&quot;1260&quot; data-origin-height=&quot;874&quot;&gt;&lt;span data-url=&quot;https://blog.kakaocdn.net/dn/lqTtr/dJMcaiXGGEq/OFlxBQejJ6qEW1lNGvEOEK/img.png&quot; data-phocus=&quot;https://blog.kakaocdn.net/dn/lqTtr/dJMcaiXGGEq/OFlxBQejJ6qEW1lNGvEOEK/img.png&quot;&gt;&lt;img src=&quot;https://blog.kakaocdn.net/dn/lqTtr/dJMcaiXGGEq/OFlxBQejJ6qEW1lNGvEOEK/img.png&quot; srcset=&quot;https://img1.daumcdn.net/thumb/R1280x0/?scode=mtistory2&amp;fname=https%3A%2F%2Fblog.kakaocdn.net%2Fdn%2FlqTtr%2FdJMcaiXGGEq%2FOFlxBQejJ6qEW1lNGvEOEK%2Fimg.png&quot; onerror=&quot;this.onerror=null; this.src='//t1.daumcdn.net/tistory_admin/static/images/no-image-v1.png'; this.srcset='//t1.daumcdn.net/tistory_admin/static/images/no-image-v1.png';&quot; loading=&quot;lazy&quot; width=&quot;1260&quot; height=&quot;874&quot; data-filename=&quot;비구조요소내진설계안내서(2026년판)표제지.png&quot; data-origin-width=&quot;1260&quot; data-origin-height=&quot;874&quot;/&gt;&lt;/span&gt;&lt;/figure&gt;
&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;table style=&quot;border-collapse: collapse; width: 100%;&quot; border=&quot;1&quot; data-ke-align=&quot;alignLeft&quot;&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style=&quot;width: 100%;&quot;&gt;&lt;span style=&quot;font-family: 'Noto Serif KR'; color: #333333;&quot;&gt;이 안내서는 시공자와 감리자가 현장에서 행정적으로 필요한 내용을 담아 이해도를 높이는 것을 주된 목적으로 작성한 것이므로 건축구조기술사가 구조역학적 안전성을 확인하는 과정인 역학적 원리&amp;middot;공식&amp;middot;기법 등에 대해서는 가급적 다루지 않습니다.&lt;/span&gt;&lt;br /&gt;&lt;span style=&quot;font-family: 'Noto Serif KR'; color: #333333;&quot;&gt;&amp;nbsp;&lt;/span&gt;&lt;br /&gt;&lt;span style=&quot;font-family: 'Noto Serif KR'; color: #333333;&quot;&gt;이 안내서는 무료로 배포되는 비매품입니다.&lt;/span&gt;&lt;br /&gt;&lt;span style=&quot;font-family: 'Noto Serif KR'; color: #333333;&quot;&gt;개인이라면 누구라도 자유롭게 사용하거나 인터넷 등에 제한 없이 공유할 수 있고, 정부, 지자체, 공공기관 ,학교 및 회사 등에서 교육용으로 사용하고 공유할 수 있습니다. 다만 회사가 영업을 위한 홍보자료로 사용하기 위하여 일부 내용만 인용하거나 일부 그림을 사용하는 것은 거부합니다. 그리고 이 책자의 내용을 전부 또는 일부를 편집 또는 가공하여 금전적 이익을 취하는 것도 거부합니다.&lt;/span&gt;&lt;br /&gt;&lt;br /&gt;&lt;span style=&quot;font-family: 'Noto Serif KR'; color: #333333;&quot;&gt;이 안내서는 비구조요소 내진설계&amp;middot;검토의 기술용역 업무를 수행한 코어건축구조기술사사무소가 업무 및 상담 경험을 토대로 작성하였습니다. 법령 및 기준 등 객관적인 근거를 기재함을 원칙으로 하되, 배경이나 취지, 판단 등에 근거가 기재되지 않은 것은 경험적 의견으로 보시기 바랍니다.&lt;/span&gt;&lt;br /&gt;&lt;span style=&quot;font-family: 'Noto Serif KR'; color: #333333;&quot;&gt;&amp;nbsp;&lt;/span&gt;&lt;br /&gt;&lt;span style=&quot;font-family: 'Noto Serif KR'; color: #333333;&quot;&gt;이 안내서를 현장 실무판단의 참고자료로 유용하게 사용하시길 바랍니다. 다만, 건설현장에서 책임구조기술자로서의 구조적 의견인 것으로 상대방을 오인시킬 의도로 작성된 문서 등에 첨부하거나 근거로 삼을 수 없고, 이해 당사자 간의 분쟁 또는 소송 등에서 다툼의 기준이나 근거로 삼을 수 없습니다.&lt;/span&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;</description>
      <category>구조상식</category>
      <category>감리자</category>
      <category>비구조</category>
      <category>비구조안내서</category>
      <category>비구조요소</category>
      <category>비구조요소내진설계</category>
      <category>시공자</category>
      <category>시공자및감리자</category>
      <category>안내서</category>
      <author>BMTARS</author>
      <guid isPermaLink="true">https://bmtars.tistory.com/316</guid>
      <comments>https://bmtars.tistory.com/316#entry316comment</comments>
      <pubDate>Sun, 24 May 2026 12:30:12 +0900</pubDate>
    </item>
    <item>
      <title>비구조요소 #F26-유리, 내진설계 대상인가?</title>
      <link>https://bmtars.tistory.com/315</link>
      <description>&lt;p&gt;&lt;figure class=&quot;imageblock alignCenter&quot; data-ke-mobileStyle=&quot;widthOrigin&quot; data-filename=&quot;blob&quot; data-origin-width=&quot;2122&quot; data-origin-height=&quot;3000&quot;&gt;&lt;span data-url=&quot;https://blog.kakaocdn.net/dn/bLbgBy/dJMcadBZZSW/ANKhNRASdfaskuK2KRcSMK/img.png&quot; data-phocus=&quot;https://blog.kakaocdn.net/dn/bLbgBy/dJMcadBZZSW/ANKhNRASdfaskuK2KRcSMK/img.png&quot;&gt;&lt;img src=&quot;https://blog.kakaocdn.net/dn/bLbgBy/dJMcadBZZSW/ANKhNRASdfaskuK2KRcSMK/img.png&quot; srcset=&quot;https://img1.daumcdn.net/thumb/R1280x0/?scode=mtistory2&amp;fname=https%3A%2F%2Fblog.kakaocdn.net%2Fdn%2FbLbgBy%2FdJMcadBZZSW%2FANKhNRASdfaskuK2KRcSMK%2Fimg.png&quot; onerror=&quot;this.onerror=null; this.src='//t1.daumcdn.net/tistory_admin/static/images/no-image-v1.png'; this.srcset='//t1.daumcdn.net/tistory_admin/static/images/no-image-v1.png';&quot; loading=&quot;lazy&quot; width=&quot;2122&quot; height=&quot;3000&quot; data-filename=&quot;blob&quot; data-origin-width=&quot;2122&quot; data-origin-height=&quot;3000&quot;/&gt;&lt;/span&gt;&lt;/figure&gt;
&lt;figure class=&quot;imageblock alignCenter&quot; data-ke-mobileStyle=&quot;widthOrigin&quot; data-filename=&quot;blob&quot; data-origin-width=&quot;2122&quot; data-origin-height=&quot;3000&quot;&gt;&lt;span data-url=&quot;https://blog.kakaocdn.net/dn/bf9Xrb/dJMcacXtEQP/KIJq9WDuf7dN3mf2Z0C1b0/img.png&quot; data-phocus=&quot;https://blog.kakaocdn.net/dn/bf9Xrb/dJMcacXtEQP/KIJq9WDuf7dN3mf2Z0C1b0/img.png&quot;&gt;&lt;img src=&quot;https://blog.kakaocdn.net/dn/bf9Xrb/dJMcacXtEQP/KIJq9WDuf7dN3mf2Z0C1b0/img.png&quot; srcset=&quot;https://img1.daumcdn.net/thumb/R1280x0/?scode=mtistory2&amp;fname=https%3A%2F%2Fblog.kakaocdn.net%2Fdn%2Fbf9Xrb%2FdJMcacXtEQP%2FKIJq9WDuf7dN3mf2Z0C1b0%2Fimg.png&quot; onerror=&quot;this.onerror=null; this.src='//t1.daumcdn.net/tistory_admin/static/images/no-image-v1.png'; this.srcset='//t1.daumcdn.net/tistory_admin/static/images/no-image-v1.png';&quot; loading=&quot;lazy&quot; width=&quot;2122&quot; height=&quot;3000&quot; data-filename=&quot;blob&quot; data-origin-width=&quot;2122&quot; data-origin-height=&quot;3000&quot;/&gt;&lt;/span&gt;&lt;/figure&gt;
&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;font-family: 'Noto Serif KR'; color: #333333;&quot;&gt;내진설계 대상입니다. 다만 기준의 예외조건에 해당한다면 내진설계 대상이 아닙니다.&lt;/span&gt;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;font-family: 'Noto Serif KR'; color: #333333;&quot;&gt;한 건축물에도 커튼월, 상점 유리, 칸막이벽, 외부 창호, 내부 창호에 다양한 크기의 유리가 설치됩니다. 프레임과 유리 사이의 유격, 즉 유리 단부 클리어런스가 충분히 크지 않으면 지진 시 발생하는 프레임의 면내 변형에 의해 유리판이 눌려 압축력이 가해지는 순간 깨집니다. 커튼월, 상점 유리, 외부 창호 등 건축물 외피에 설치되는 유리판의 상단 높이가 보행자 도로면으로부터 3m가 넘으면 유리 깨짐과 함께 추락하면서 인명에 위협이 됩니다. 또 칸막이벽, 내부 창호, 방풍실 등의 유리가 건축물 피난경로에 그 유리가 깨져서 바닥에 깔리면 미끄러짐 등으로 신속한 대피 활동에 지장을 초래할 수도 있습니다.&lt;/span&gt;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;font-family: 'Noto Serif KR'; color: #333333;&quot;&gt;지진 시 유리 파괴(깨짐) 메커니즘은 3단계로 설명하면,&amp;nbsp;&lt;/span&gt;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;font-family: 'Noto Serif KR'; color: #333333;&quot;&gt;(a) 지진 시 건축물의 층간 변위가 발생하기 시작하는 순간, 구조체에 정착&amp;middot;구속된 프레임(창틀)도 변형이 시작되며, 프레임 속 유리판도 프레임 변형에 따라 수평으로 이동합니다.&lt;/span&gt;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;font-family: 'Noto Serif KR'; color: #333333;&quot;&gt;(b) 건축물의 층간 변위가 커지면서 이에 종속된 프레임의 변형(상대 수평변위)도 커지며, 변형된 프레임이 변형하지 않는 유리판에 접하기 시작하면 유리판에 힘이 작용하기 시작하며 이때 유리판은 응력으로 저항하지 않고 유격(단부 클리어런스) 범위 내에서 회전하여 변형하는 것으로 해소합니다.&lt;/span&gt;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;font-family: 'Noto Serif KR'; color: #333333;&quot;&gt;(c) 건축물의 층간 변위가 더욱 커지면 이에 따라 프레임도 점차 두드러진 평행사변형의 형상으로 변형하고, 어느 순간에 유리판이 더 이상 회전할 수 없는 구속 상태가 되면 유리판에 작용하는 힘이 압축력으로서 증가하며, 그 압축력이 유리판의 응력을 초과하는 순간에 유리판은 취성파괴, 즉 갑자기 깨집니다.&lt;/span&gt;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;color: #333333;&quot;&gt;&lt;span style=&quot;font-family: 'Noto Serif KR';&quot;&gt;관련 동영상 링크 (포항지진 상점 유리 깨짐) &lt;/span&gt;&lt;span style=&quot;font-family: 'Noto Serif KR';&quot;&gt;:&lt;/span&gt; &lt;/span&gt;&lt;a href=&quot;https://www.youtube.com/watch?v=WFMzLAKNCMw&quot;&gt;&lt;u&gt;&lt;span style=&quot;color: #0000ff;&quot;&gt;YouTube [&lt;/span&gt;&lt;/u&gt;&lt;u&gt;&lt;span style=&quot;color: #0000ff;&quot;&gt;출처&lt;/span&gt;&lt;/u&gt;&lt;u&gt;&lt;span style=&quot;color: #0000ff;&quot;&gt;: YTN]&lt;/span&gt;&lt;/u&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;font-family: 'Noto Serif KR'; color: #333333;&quot;&gt;구조물에 내진설계로 반영된 설계 지진에서도 이러한 유리들이 깨지지 않으려면 유리와 프레임 사이에 요구되는 유격, 즉 &amp;lsquo;단부 클리어런스&amp;rsquo; 요구치수를 내진설계를 통해 확인하고, 창호 제작 시에 반영되도록 하여야 합니다. 창호 전체 시스템에 대한 Mock-up test(구조성능실험) 또는 프레임 구조검토 용역 발주시에 유리 깨짐에 대한 내진검토를 포함하는 것으로 조건을 붙이거나, 또는 유리 깨짐에 대해서만 별도로 내진설계를 의뢰할 수도 있습니다.&lt;/span&gt;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;font-family: 'Noto Serif KR'; color: #333333;&quot;&gt;건축물마다 유리가 설치되는 창호의 종류, 위치, 크기는 제각각인데, 이 유리가 깨져서 추락하거나 피난경로를 통한 대피 활동에 지장을 초래하여 &amp;lsquo;인명안전&amp;rsquo;에 위협이 될 수 있고, 건축물의 &amp;lsquo;기능수행&amp;rsquo;에 지장을 초래할 수 있습니다. 이러한 유리들이 예외조건에 해당하지 않는다면 내진설계 대상입니다.&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;color: #333333; text-align: start;&quot; data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;table style=&quot;border-collapse: collapse; width: 100%;&quot; border=&quot;1&quot; data-ke-align=&quot;alignLeft&quot;&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style=&quot;width: 100%;&quot;&gt;&lt;span style=&quot;color: #9d9d9d;&quot;&gt;개인이라면 누구라도 자유롭게 사용하거나 인터넷 등에 제한 없이 공유할 수 있고, 정부, 지자체, 공공기관 ,학교 및 회사 등에서 교육용으로 사용하고 공유할 수 있습니다. 공유시에는 출처를 표기하여야 합니다. 다만 회사가 영업을 위한 홍보자료로 사용하기 위하여 일부 내용만 인용하거나 일부 그림을 사용하는 것은 거부합니다. 그리고 이 책자의 내용을 전부 또는 일부를 편집 또는 가공하여 금전적 이익을 취하는 것도 거부합니다. 이 내용을 현장 실무판단의 참고자료로 유용하게 사용하시길 바랍니다. 다만, 건설현장에서 책임구조기술자로서의 구조적 의견인 것으로 상대방을 오인시킬 의도로 작성된 문서 등에 첨부하거나 근거로 삼을 수 없고, 이해 당사자 간의 분쟁 또는 소송 등에서 다툼의 기준이나 근거로 삼을 수 없습니다.&lt;/span&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p style=&quot;color: #333333; text-align: start;&quot; data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p style=&quot;color: #333333; text-align: start;&quot; data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;font-family: 'Noto Sans Light'; color: #333333; text-align: start;&quot;&gt;제공 :&lt;span&gt;&amp;nbsp;&lt;/span&gt;&lt;/span&gt;&lt;a style=&quot;font-family: 'Noto Sans Light'; color: #0070d1; text-align: start;&quot; href=&quot;http://www.corest.co.kr&quot;&gt;&lt;span style=&quot;font-family: 'Noto Sans Demilight', 'Noto Sans KR';&quot;&gt;코어건축구조기술사사무소&lt;/span&gt;&lt;/a&gt;&lt;/p&gt;</description>
      <category>구조상식</category>
      <category>비구조</category>
      <category>비구조요소</category>
      <category>유격</category>
      <category>유리</category>
      <category>유리깨짐</category>
      <category>유리칸막이벽</category>
      <category>커튼월</category>
      <category>클라이언스</category>
      <author>BMTARS</author>
      <guid isPermaLink="true">https://bmtars.tistory.com/315</guid>
      <comments>https://bmtars.tistory.com/315#entry315comment</comments>
      <pubDate>Thu, 21 May 2026 00:47:59 +0900</pubDate>
    </item>
    <item>
      <title>비구조요소 #F25-케이블트레이 등 매달린 비구조요소에 내진스프링장치 설치시 주의사항은?</title>
      <link>https://bmtars.tistory.com/314</link>
      <description>&lt;p&gt;&lt;figure class=&quot;imageblock alignCenter&quot; data-ke-mobileStyle=&quot;widthOrigin&quot; data-filename=&quot;blob&quot; data-origin-width=&quot;2122&quot; data-origin-height=&quot;3000&quot;&gt;&lt;span data-url=&quot;https://blog.kakaocdn.net/dn/q6eDb/dJMcagewytH/uB2MK9uR4eJV3u3YsioD3K/img.png&quot; data-phocus=&quot;https://blog.kakaocdn.net/dn/q6eDb/dJMcagewytH/uB2MK9uR4eJV3u3YsioD3K/img.png&quot;&gt;&lt;img src=&quot;https://blog.kakaocdn.net/dn/q6eDb/dJMcagewytH/uB2MK9uR4eJV3u3YsioD3K/img.png&quot; srcset=&quot;https://img1.daumcdn.net/thumb/R1280x0/?scode=mtistory2&amp;fname=https%3A%2F%2Fblog.kakaocdn.net%2Fdn%2Fq6eDb%2FdJMcagewytH%2FuB2MK9uR4eJV3u3YsioD3K%2Fimg.png&quot; onerror=&quot;this.onerror=null; this.src='//t1.daumcdn.net/tistory_admin/static/images/no-image-v1.png'; this.srcset='//t1.daumcdn.net/tistory_admin/static/images/no-image-v1.png';&quot; loading=&quot;lazy&quot; width=&quot;2122&quot; height=&quot;3000&quot; data-filename=&quot;blob&quot; data-origin-width=&quot;2122&quot; data-origin-height=&quot;3000&quot;/&gt;&lt;/span&gt;&lt;/figure&gt;
&lt;/p&gt;
&lt;p style=&quot;color: #333333; text-align: start;&quot; data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;font-family: 'Noto Serif KR';&quot;&gt;&lt;span style=&quot;color: #333333;&quot;&gt;매달린 전기&amp;middot;기계 비구조요소 내진을 적용하는 방식은 대표적으로 세 가지가 있습니다.(&lt;/span&gt;&lt;span style=&quot;background-color: #b900b9; color: #ffffff;&quot;&gt; &lt;/span&gt;&lt;span style=&quot;background-color: #b900b9; color: #ffffff;&quot;&gt;F14 &lt;/span&gt; &lt;span style=&quot;color: #333333;&quot;&gt;참조)&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;font-family: 'Noto Serif KR'; color: #333333;&quot;&gt;그 중에서 내진스프링장치를 설치하는 경우에는 매달린 비구조요소를 지지하는 모든 전산볼트(행거)에 설치되어야 하고, 내진설계&amp;middot;검토를 통해서 계산&amp;middot;제시된 최적 위치에 설치되어야 합니다.&lt;/span&gt;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;font-family: 'Noto Serif KR'; color: #333333;&quot;&gt;일부 전산볼트에만 부분적으로 내진스프링장치를 설치하는 경우에는 내진스프링장치를 전혀 사용하지 않는 경우보다 오히려 더 큰 변형이 발생하며, 이때 내진스프링장치를 설치하지 않은 경우에는 역학적으로 전산볼트의 상단 정착부에서 파단될 가능성이 높습니다. 즉 부분적으로 일부 전산볼트에만 내진스프링장치를 설치하면 그 설치 비율만큼 성능 효과는 발생하지 않습니다.&amp;nbsp;오히려 연성휨거동으로 작용하는 지진하중의 전달 경로가 내진스프링장치를 설치하지 않은 전산볼트 경로로 집중되어 전달되므로 전체시스템의 수평변위가 크게 발생하며, 전산볼트의 과대한 변형에 의해 파단하는 역효과가 발생하므로 더욱 위험합니다.&lt;/span&gt;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;font-family: 'Noto Serif KR'; color: #333333;&quot;&gt;재래방식의 내진지지대뿐만 아니라, 신공법의 내진스프링장치도 비구조요소 내진설계&amp;middot;검토는 필수입니다.&lt;/span&gt;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;font-family: 'Noto Serif KR'; color: #333333;&quot;&gt;내진스프링장치는 설치하기만 하면 안전한 것이 아니라, 전산볼트 중 어느 위치에 설치되는지에 따라서 내진성능효과가 크게 달라지기 때문입니다. 전산볼트의 파단을 방지하는 강도 안전성, 수평변위 안정성, 공진효과 회피 가능성에 대해 종합적으로 내진설계&amp;middot;검토된 위치에 설치되어야만 최적의 효과가 발휘될 수 있습니다.&lt;/span&gt;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;font-family: 'Noto Serif KR';&quot;&gt;비교실험 동영상 링크 &lt;/span&gt;&lt;span&gt;&lt;span style=&quot;font-family: 'Noto Serif KR';&quot;&gt;:&lt;/span&gt; &lt;/span&gt;&lt;a href=&quot;https://www.youtube.com/watch?v=gkdhcA5FV24&quot; target=&quot;_blank&quot; rel=&quot;noopener&quot;&gt;&lt;u&gt;&lt;span style=&quot;color: #0000ff;&quot;&gt;YouTube &lt;/span&gt;&lt;/u&gt;&lt;u&gt;&lt;span style=&quot;color: #0000ff;&quot;&gt;[&lt;/span&gt;&lt;/u&gt;&lt;u&gt;&lt;span style=&quot;color: #0000ff;&quot;&gt;출처&lt;/span&gt;&lt;/u&gt;&lt;u&gt;&lt;span style=&quot;color: #0000ff;&quot;&gt;: &lt;/span&gt;&lt;/u&gt;&lt;u&gt;&lt;span style=&quot;color: #0000ff;&quot;&gt;범호정공&lt;/span&gt;&lt;/u&gt;&lt;u&gt;&lt;span style=&quot;color: #0000ff;&quot;&gt;]&lt;/span&gt;&lt;/u&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p style=&quot;color: #333333; text-align: start;&quot; data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;font-family: 'Noto Serif KR'; color: #333333;&quot;&gt;내진스프링장치는 경사재(내진지지대) 설치가 불필요하므로 타공종 설비와의 간섭에 대한 부담이 적고 설치가 간편하지만, 모든 전산볼트에 설치되어야 하고 또 최적 위치에 설치되어야 합니다.&lt;/span&gt;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;font-family: 'Noto Serif KR'; color: #333333;&quot;&gt;타공종 설비와 간섭 우려가 없는 환경에서 재래식 내진지지대 방식을 적용하려면 ｢건축물 전기설비 내진 설계기준(KDS 32 17 00)｣ 4.2~4항 조건에 따라 실시된 내진설계 결과를 준수하여 시공하면 됩니다.&lt;/span&gt;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;table style=&quot;border-collapse: collapse; width: 100%;&quot; border=&quot;1&quot; data-ke-align=&quot;alignLeft&quot;&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style=&quot;width: 100%;&quot;&gt;&lt;span style=&quot;color: #9d9d9d;&quot;&gt;개인이라면 누구라도 자유롭게 사용하거나 인터넷 등에 제한 없이 공유할 수 있고, 정부, 지자체, 공공기관 ,학교 및 회사 등에서 교육용으로 사용하고 공유할 수 있습니다. 공유시에는 출처를 표기하여야 합니다. 다만 회사가 영업을 위한 홍보자료로 사용하기 위하여 일부 내용만 인용하거나 일부 그림을 사용하는 것은 거부합니다. 그리고 이 책자의 내용을 전부 또는 일부를 편집 또는 가공하여 금전적 이익을 취하는 것도 거부합니다. 이 내용을 현장 실무판단의 참고자료로 유용하게 사용하시길 바랍니다. 다만, 건설현장에서 책임구조기술자로서의 구조적 의견인 것으로 상대방을 오인시킬 의도로 작성된 문서 등에 첨부하거나 근거로 삼을 수 없고, 이해 당사자 간의 분쟁 또는 소송 등에서 다툼의 기준이나 근거로 삼을 수 없습니다.&lt;/span&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p style=&quot;color: #333333; text-align: start;&quot; data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p style=&quot;color: #333333; text-align: start;&quot; data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;font-family: 'Noto Sans Light'; color: #333333; text-align: start;&quot;&gt;제공 :&lt;span&gt;&amp;nbsp;&lt;/span&gt;&lt;/span&gt;&lt;a style=&quot;font-family: 'Noto Sans Light'; color: #0070d1; text-align: start;&quot; href=&quot;http://www.corest.co.kr&quot;&gt;&lt;span style=&quot;font-family: 'Noto Sans Demilight', 'Noto Sans KR';&quot;&gt;코어건축구조기술사사무소&lt;/span&gt;&lt;/a&gt;&lt;/p&gt;</description>
      <category>구조상식</category>
      <category>기계비구조요소</category>
      <category>내진스프링</category>
      <category>노출전선관</category>
      <category>레이스웨이</category>
      <category>버스덕트</category>
      <category>부스덕트</category>
      <category>비구조</category>
      <category>비구조요소</category>
      <category>전기비구조요소</category>
      <category>케이블트레이</category>
      <author>BMTARS</author>
      <guid isPermaLink="true">https://bmtars.tistory.com/314</guid>
      <comments>https://bmtars.tistory.com/314#entry314comment</comments>
      <pubDate>Thu, 21 May 2026 00:39:10 +0900</pubDate>
    </item>
    <item>
      <title>비구조요소 #F24-매달린 전기 비구조요소에 신공법&amp;middot;특수공법 적용이 가능한지?</title>
      <link>https://bmtars.tistory.com/313</link>
      <description>&lt;p&gt;&lt;figure class=&quot;imageblock alignCenter&quot; data-ke-mobileStyle=&quot;widthOrigin&quot; data-filename=&quot;blob&quot; data-origin-width=&quot;2122&quot; data-origin-height=&quot;3000&quot;&gt;&lt;span data-url=&quot;https://blog.kakaocdn.net/dn/bexqhW/dJMcai4phKa/NftmTK18MEkAFXAUTtnD10/img.png&quot; data-phocus=&quot;https://blog.kakaocdn.net/dn/bexqhW/dJMcai4phKa/NftmTK18MEkAFXAUTtnD10/img.png&quot;&gt;&lt;img src=&quot;https://blog.kakaocdn.net/dn/bexqhW/dJMcai4phKa/NftmTK18MEkAFXAUTtnD10/img.png&quot; srcset=&quot;https://img1.daumcdn.net/thumb/R1280x0/?scode=mtistory2&amp;fname=https%3A%2F%2Fblog.kakaocdn.net%2Fdn%2FbexqhW%2FdJMcai4phKa%2FNftmTK18MEkAFXAUTtnD10%2Fimg.png&quot; onerror=&quot;this.onerror=null; this.src='//t1.daumcdn.net/tistory_admin/static/images/no-image-v1.png'; this.srcset='//t1.daumcdn.net/tistory_admin/static/images/no-image-v1.png';&quot; loading=&quot;lazy&quot; width=&quot;2122&quot; height=&quot;3000&quot; data-filename=&quot;blob&quot; data-origin-width=&quot;2122&quot; data-origin-height=&quot;3000&quot;/&gt;&lt;/span&gt;&lt;/figure&gt;
&lt;/p&gt;
&lt;p style=&quot;color: #333333; text-align: start;&quot; data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;font-family: 'Noto Serif KR';&quot;&gt;신공법&amp;middot;특수공법 적용은 유효합니다. &lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;color: #333333; text-align: start;&quot; data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;font-family: 'Noto Serif KR';&quot;&gt;국가건설기준센터는 설계 시 &amp;lsquo;설계기준에 명시되어 있지 않은 신기술, 신공법이라도 발주자의 승인을 얻어 적용할 수 있다&amp;rsquo;고 판단하였습니다. &lt;/span&gt;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;font-family: 'Noto Serif KR';&quot;&gt;시공 시에는 표준시방서 「전기설비 일반사항(KDS 32 10 10)」 1.8항에 의거, &amp;lsquo;&lt;u&gt;국가 및 국가 기관&lt;/u&gt;&lt;u&gt;에서 인증&lt;/u&gt;한 신공법&amp;middot;특수공법을 우선하여 적용&amp;rsquo;할 수 있습니다.&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;color: #333333; text-align: start;&quot; data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p style=&quot;color: #333333; text-align: start;&quot; data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;font-family: 'Noto Serif KR';&quot;&gt;상기 Q&amp;amp;A 전문 링크&lt;/span&gt;&lt;span&gt;&lt;span style=&quot;font-family: 'Noto Serif KR';&quot;&gt;:&lt;/span&gt; &lt;/span&gt;&lt;u&gt;&lt;span style=&quot;color: #0000ff;&quot;&gt;&lt;/span&gt;&lt;/u&gt;&lt;u&gt;&lt;a title=&quot;국가건설기준센터 Q&amp;amp;A&quot; href=&quot;https://www.kcsc.re.kr/board/qnadetail/8926&quot; target=&quot;_blank&quot; rel=&quot;noopener&quot;&gt;https://www.kcsc.re.kr/board/qnadetail/8926&lt;/a&gt;&lt;/u&gt;&lt;/p&gt;
&lt;p style=&quot;color: #333333; text-align: start;&quot; data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;table style=&quot;border-collapse: collapse; width: 100%;&quot; border=&quot;1&quot; data-ke-align=&quot;alignLeft&quot;&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style=&quot;width: 100%;&quot;&gt;&lt;span style=&quot;color: #9d9d9d;&quot;&gt;개인이라면 누구라도 자유롭게 사용하거나 인터넷 등에 제한 없이 공유할 수 있고, 정부, 지자체, 공공기관 ,학교 및 회사 등에서 교육용으로 사용하고 공유할 수 있습니다. 공유시에는 출처를 표기하여야 합니다. 다만 회사가 영업을 위한 홍보자료로 사용하기 위하여 일부 내용만 인용하거나 일부 그림을 사용하는 것은 거부합니다. 그리고 이 책자의 내용을 전부 또는 일부를 편집 또는 가공하여 금전적 이익을 취하는 것도 거부합니다. 이 내용을 현장 실무판단의 참고자료로 유용하게 사용하시길 바랍니다. 다만, 건설현장에서 책임구조기술자로서의 구조적 의견인 것으로 상대방을 오인시킬 의도로 작성된 문서 등에 첨부하거나 근거로 삼을 수 없고, 이해 당사자 간의 분쟁 또는 소송 등에서 다툼의 기준이나 근거로 삼을 수 없습니다.&lt;/span&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p style=&quot;color: #333333; text-align: start;&quot; data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p style=&quot;color: #333333; text-align: start;&quot; data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;font-family: 'Noto Sans Light'; color: #333333; text-align: start;&quot;&gt;제공 :&lt;span&gt;&amp;nbsp;&lt;/span&gt;&lt;/span&gt;&lt;a style=&quot;font-family: 'Noto Sans Light'; color: #0070d1; text-align: start;&quot; href=&quot;http://www.corest.co.kr&quot;&gt;&lt;span style=&quot;font-family: 'Noto Sans Demilight', 'Noto Sans KR';&quot;&gt;코어건축구조기술사사무소&lt;/span&gt;&lt;/a&gt;&lt;/p&gt;
&lt;p style=&quot;color: #333333; text-align: start;&quot; data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p style=&quot;color: #333333; text-align: start;&quot; data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;</description>
      <category>구조상식</category>
      <category>매달린</category>
      <category>비구조</category>
      <category>비구조요소</category>
      <category>신공법</category>
      <category>신기술</category>
      <category>전기비구조요소</category>
      <author>BMTARS</author>
      <guid isPermaLink="true">https://bmtars.tistory.com/313</guid>
      <comments>https://bmtars.tistory.com/313#entry313comment</comments>
      <pubDate>Thu, 21 May 2026 00:29:15 +0900</pubDate>
    </item>
    <item>
      <title>비구조요소 #F23-기계 비구조요소 중 내진설계 대상은?</title>
      <link>https://bmtars.tistory.com/312</link>
      <description>&lt;p&gt;&lt;figure class=&quot;imageblock alignCenter&quot; data-ke-mobileStyle=&quot;widthOrigin&quot; data-filename=&quot;blob&quot; data-origin-width=&quot;2122&quot; data-origin-height=&quot;3000&quot;&gt;&lt;span data-url=&quot;https://blog.kakaocdn.net/dn/bD48ZD/dJMcacpFA4n/ikSuDYDVgzG3zccmYCB0c0/img.png&quot; data-phocus=&quot;https://blog.kakaocdn.net/dn/bD48ZD/dJMcacpFA4n/ikSuDYDVgzG3zccmYCB0c0/img.png&quot;&gt;&lt;img src=&quot;https://blog.kakaocdn.net/dn/bD48ZD/dJMcacpFA4n/ikSuDYDVgzG3zccmYCB0c0/img.png&quot; srcset=&quot;https://img1.daumcdn.net/thumb/R1280x0/?scode=mtistory2&amp;fname=https%3A%2F%2Fblog.kakaocdn.net%2Fdn%2FbD48ZD%2FdJMcacpFA4n%2FikSuDYDVgzG3zccmYCB0c0%2Fimg.png&quot; onerror=&quot;this.onerror=null; this.src='//t1.daumcdn.net/tistory_admin/static/images/no-image-v1.png'; this.srcset='//t1.daumcdn.net/tistory_admin/static/images/no-image-v1.png';&quot; loading=&quot;lazy&quot; width=&quot;2122&quot; height=&quot;3000&quot; data-filename=&quot;blob&quot; data-origin-width=&quot;2122&quot; data-origin-height=&quot;3000&quot;/&gt;&lt;/span&gt;&lt;/figure&gt;
&lt;figure class=&quot;imageblock alignCenter&quot; data-ke-mobileStyle=&quot;widthOrigin&quot; data-filename=&quot;blob&quot; data-origin-width=&quot;2122&quot; data-origin-height=&quot;3000&quot;&gt;&lt;span data-url=&quot;https://blog.kakaocdn.net/dn/dr4PW8/dJMcaiJ7ClV/wHwfoxf9UHHpT7QoXxT1lK/img.png&quot; data-phocus=&quot;https://blog.kakaocdn.net/dn/dr4PW8/dJMcaiJ7ClV/wHwfoxf9UHHpT7QoXxT1lK/img.png&quot;&gt;&lt;img src=&quot;https://blog.kakaocdn.net/dn/dr4PW8/dJMcaiJ7ClV/wHwfoxf9UHHpT7QoXxT1lK/img.png&quot; srcset=&quot;https://img1.daumcdn.net/thumb/R1280x0/?scode=mtistory2&amp;fname=https%3A%2F%2Fblog.kakaocdn.net%2Fdn%2Fdr4PW8%2FdJMcaiJ7ClV%2FwHwfoxf9UHHpT7QoXxT1lK%2Fimg.png&quot; onerror=&quot;this.onerror=null; this.src='//t1.daumcdn.net/tistory_admin/static/images/no-image-v1.png'; this.srcset='//t1.daumcdn.net/tistory_admin/static/images/no-image-v1.png';&quot; loading=&quot;lazy&quot; width=&quot;2122&quot; height=&quot;3000&quot; data-filename=&quot;blob&quot; data-origin-width=&quot;2122&quot; data-origin-height=&quot;3000&quot;/&gt;&lt;/span&gt;&lt;/figure&gt;
&lt;figure class=&quot;imageblock alignCenter&quot; data-ke-mobileStyle=&quot;widthOrigin&quot; data-filename=&quot;blob&quot; data-origin-width=&quot;2122&quot; data-origin-height=&quot;3000&quot;&gt;&lt;span data-url=&quot;https://blog.kakaocdn.net/dn/s10XW/dJMcabdaf4s/PkPOBx7CEdTyHL7thSh5AK/img.png&quot; data-phocus=&quot;https://blog.kakaocdn.net/dn/s10XW/dJMcabdaf4s/PkPOBx7CEdTyHL7thSh5AK/img.png&quot;&gt;&lt;img src=&quot;https://blog.kakaocdn.net/dn/s10XW/dJMcabdaf4s/PkPOBx7CEdTyHL7thSh5AK/img.png&quot; srcset=&quot;https://img1.daumcdn.net/thumb/R1280x0/?scode=mtistory2&amp;fname=https%3A%2F%2Fblog.kakaocdn.net%2Fdn%2Fs10XW%2FdJMcabdaf4s%2FPkPOBx7CEdTyHL7thSh5AK%2Fimg.png&quot; onerror=&quot;this.onerror=null; this.src='//t1.daumcdn.net/tistory_admin/static/images/no-image-v1.png'; this.srcset='//t1.daumcdn.net/tistory_admin/static/images/no-image-v1.png';&quot; loading=&quot;lazy&quot; width=&quot;2122&quot; height=&quot;3000&quot; data-filename=&quot;blob&quot; data-origin-width=&quot;2122&quot; data-origin-height=&quot;3000&quot;/&gt;&lt;/span&gt;&lt;/figure&gt;
&lt;figure class=&quot;imageblock alignCenter&quot; data-ke-mobileStyle=&quot;widthOrigin&quot; data-filename=&quot;blob&quot; data-origin-width=&quot;2122&quot; data-origin-height=&quot;3000&quot;&gt;&lt;span data-url=&quot;https://blog.kakaocdn.net/dn/AMmmJ/dJMcagFCSgt/UyNdujomHg5pG0vwXT6OxK/img.png&quot; data-phocus=&quot;https://blog.kakaocdn.net/dn/AMmmJ/dJMcagFCSgt/UyNdujomHg5pG0vwXT6OxK/img.png&quot;&gt;&lt;img src=&quot;https://blog.kakaocdn.net/dn/AMmmJ/dJMcagFCSgt/UyNdujomHg5pG0vwXT6OxK/img.png&quot; srcset=&quot;https://img1.daumcdn.net/thumb/R1280x0/?scode=mtistory2&amp;fname=https%3A%2F%2Fblog.kakaocdn.net%2Fdn%2FAMmmJ%2FdJMcagFCSgt%2FUyNdujomHg5pG0vwXT6OxK%2Fimg.png&quot; onerror=&quot;this.onerror=null; this.src='//t1.daumcdn.net/tistory_admin/static/images/no-image-v1.png'; this.srcset='//t1.daumcdn.net/tistory_admin/static/images/no-image-v1.png';&quot; loading=&quot;lazy&quot; width=&quot;2122&quot; height=&quot;3000&quot; data-filename=&quot;blob&quot; data-origin-width=&quot;2122&quot; data-origin-height=&quot;3000&quot;/&gt;&lt;/span&gt;&lt;/figure&gt;
&lt;/p&gt;
&lt;p style=&quot;color: #333333; text-align: start;&quot; data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;font-family: 'Noto Serif KR';&quot;&gt;전기와 마찬가지로 기계설비에 대해서도 2026년 2월 23일에 KDS 31 70 20 「기계설비 내진」 기준이 제정되었습니다. 기계 비구조요소 중 소방 관련 기계설비는 「소방시설의 내진설계 기준」에 따라 필수 내진설계&amp;middot;검토의 대상으로서 본 장에서 재차 거론하지 않으며, 소방과 관련 없는 기계 비구조요소의 내진설계 대상을 안내합니다.&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;color: #333333; text-align: start;&quot; data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p style=&quot;color: #333333; text-align: start;&quot; data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;font-family: 'Noto Serif KR';&quot;&gt;&lt;span style=&quot;color: #ff0000;&quot;&gt;[1]&lt;/span&gt;&lt;span style=&quot;color: #ff0000;&quot;&gt; &lt;/span&gt;: 독성&amp;middot;가스&amp;middot;배연 관련 기계설비는 인명안전과 직결되므로 필수 대상입니다. 중요도계수가 1.5인 위험물질과 관련된 비구조요소 본체는 제조자가 정밀해석과 진동대 실험 등을 통해 해당 설계지진 시에도 위험물질이 유출되지 않음을 증명(KDS 41 17 00, 18.1.3.4(1)②)하여야 합니다. 그 정착부 및 배연 관련 기계설비는 내진검토 대상입니다. 독성&amp;middot;가스&amp;middot;배연 관련 기계설비에 속하지 않지만 전도 또는 추락하면 이러한 설비에 손상을 줄 수 있는 위치에 설치되는 비구조요소도 내진검토 대상입니다.&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;color: #333333; text-align: start;&quot; data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p style=&quot;color: #333333; text-align: start;&quot; data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;font-family: 'Noto Serif KR';&quot;&gt;&lt;span style=&quot;color: #ff6600;&quot;&gt;[2]&lt;/span&gt;&lt;span style=&quot;color: #ff0000;&quot;&gt; &lt;/span&gt;: 내진특등급 건축물의 기계설비 중에서 아래 두 가지 중에 속하는 기계 비구조요소가 해당됩니다. &lt;/span&gt;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;font-family: 'Noto Serif KR';&quot;&gt; ① 중요한 기능을 갖는 설비로서 지속적인 기능수행이 요구되는 기계 비구조요소&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;text-align: left;&quot; data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;font-family: 'Noto Serif KR';&quot;&gt; ② 그 자체는 중요하지 않지만, 파괴되어 추락 또는 전도되면 중요한 장치를 손상시켜 시설물의 지속적인 가동에 지장을 줄 수 있는 위치에 설치되는 기계 비구조요소&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;text-align: left;&quot; data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;font-family: 'Noto Serif KR';&quot;&gt; 다양한 기계 비구조요소 중에서 상기에 해당하는 내진설계&amp;middot;검토 대상을 결정하는 것은 건축주(발주처/사용주체)와 건설전문가(감리자/시공자)가 함께 협의하여 결정하는 것이 바람직합니다. 지진 시에도 파괴되지 않고 지진 후에도 가동되어야 하는 핵심 설비가 어떤 것인지는 시설물의 운영에 관한 계획&amp;middot;방침&amp;middot;경험 등을 보유한 운영주체인 건축주(발주처/사용주체)만이 특정할 수 있습니다. 또한 건축주가 특정한 핵심 설비에 대해서 다양한 공종 및 계통설비 중 손상을 일으킬 수 있는 비구조요소는 공사계획을 파악한 건설전문가가 추려내 특정할 수 있습니다. 상호 긴밀한 협력과 논의를 통해서만이 합리적이고 효율적인 결정, 즉 불필요한 예산낭비를 방지하면서 기능수행 능력을 안정적으로 확보할 수 있는 결정에 도달할 수 있습니다.&lt;/span&gt;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;font-family: 'Noto Serif KR';&quot;&gt; 내진특등급이 아닌 시설물이더라도 냉장창고의 냉동&amp;middot;냉장설비와 같이 지진 후에도 지속 가동되어야 한다고 건축주가 판단한다면 기준(KDS 41 17 00) 18.1.1의 (3)항에 따라 건축주는 시공자와 협의하여 자율적으로 검토 진행을 결정할 수 있습니다.&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;text-align: left;&quot; data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;font-family: 'Noto Serif KR';&quot;&gt;&lt;span style=&quot;color: #008000;&quot;&gt;[3]&lt;/span&gt;&lt;span style=&quot;color: #ff0000;&quot;&gt; &lt;/span&gt;: &lt;span style=&quot;color: #ff0000;&quot;&gt;[1]&lt;/span&gt;, &lt;span style=&quot;color: #ff6600;&quot;&gt;[2]&lt;/span&gt;에 해당하지 않는 바닥설치형 기계설비 냉난방실외기&amp;middot;펌프&amp;middot;보일러 등은 정착부가 튼튼하지 않으면 지진 시 전도될 수 있습니다. &lt;u&gt;전도 시 사람을 덮칠 수 있는 위치에 설치될 경우에는&lt;/u&gt;&lt;u&gt; &lt;/u&gt;&lt;u&gt;인명안전을 위협하는 요소로서&lt;/u&gt;&lt;u&gt; &lt;/u&gt;&lt;u&gt;내진검토 대상&lt;/u&gt;입니다. 바닥설치형 기계설비가 기계실/옥상휀스구역 등 출입통제되는 곳에 설치되면 지진 시 전도되더라도 인명안전에 위협이 될 가능성은 낮습니다. 내진검토보다 더욱 근본적이고 효과적인 조치는 관리적 측면에 있다고 여겨집니다. 접근 통제구역 설정&amp;middot;관리, 관리자 재난안전 행동수칙 수립&amp;middot;관리, 2차 전도될 수 있는 휀스를 장비높이 이상 적정하게 이격하여 설치하는 것 등등 세심한 관리적 예방조치가 더욱 중요합니다. 그러나 이러한 관리적 예방조치를 할 수 없거나, 하더라도 인명안전의 위협이 있다고 우려되면 내진검토를 통해 정착부가 충분히 안전한지 확인하고 보강할 수 있습니다. &lt;/span&gt;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;font-family: 'Noto Serif KR';&quot;&gt; 중량 1,800N(≒183kg)를 초과하는 바닥설치형 전기설비는 내진검토를 통해 정착부의 안전성을 검토합니다. 중량 1,800N 이하면서 450N(≒45.9kg)를 초과하는 장비는 제품공급 제조사가 인증하는 방법으로 설치 시 정착부에 대한 내진검토를 생략할 수 있습니다. &lt;/span&gt;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;font-family: 'Noto Serif KR';&quot;&gt; 중량 450N 이하의 장비를 내력벽면 또는 기둥에 설치하는 경우 직경 8㎜ 이상의 고정용 볼트 4개 이상으로 고정(「소방시설의 내진설계 기준」, 제14조제1항)하면 그 정착부에 대한 내진검토를 생략할 수 있습니다.&lt;/span&gt;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;font-family: 'Noto Serif KR';&quot;&gt; 내진검토 대상이 되는 비구조요소를 지지하는 콘크리트 기초는 구조안전성을 확인하여야 하며, 다만 바닥 구조체와 동시 타설되어 완벽히 일체화된 경우에는 검토 범위에서 제외할 수 있다는 의견입니다.&lt;/span&gt;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;font-family: 'Noto Serif KR';&quot;&gt; 비구조요소와 바닥정착부 사이에 지지부(내진받침대 또는 선반지지대 등)가 있다면, 역시 인명안전에 위협이 될 수 있는 위치에 설치될 경우에는 지지부와 그 정착부는 내진검토의 대상입니다.&lt;/span&gt;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;font-family: 'Noto Serif KR';&quot;&gt;&lt;span style=&quot;color: #0000ff;&quot;&gt;[4]&lt;/span&gt;&lt;span style=&quot;color: #ff0000;&quot;&gt; &lt;/span&gt;: 천정설치형 기계설비 중에서, 장비(장비)는 중량 100N(≒10.2kg) 초과, 배관&amp;middot;덕트는 단위길이당 중량이 70N/m(≒7.1kg/m)를 초과하는 무거운 것은 지진시 과도하게 흔들리면 행거볼트가 파단되어 추락할 수 있으며, 이때 &lt;u&gt;매달리는 무거운 기계설비가 생활공간이나 피난경로 상에 배치&lt;/u&gt;&lt;u&gt;되는 경우에는 인명안전을 위협하므로 내진검토 대상&lt;/u&gt;입니다.&lt;/span&gt;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;font-family: 'Noto Serif KR';&quot;&gt; 매달리는 장비로서 전산볼트 등 행거에 매달리는 장비(냉난방실내기&amp;middot;전열교환기 등)의 비구조요소가 &lt;span style=&quot;color: #ff0000;&quot;&gt;[1]&lt;/span&gt;, &lt;span style=&quot;color: #ff6600;&quot;&gt;[2]&lt;/span&gt;에 해당하지 않으면서 그 중량이 100N 미만이면 내진검토를 생략할 수 있습니다.&lt;/span&gt;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;font-family: 'Noto Serif KR';&quot;&gt; 전산볼트 등 행거에 매달리는 배관&amp;middot;덕트 등의 비구조요소가 &lt;span style=&quot;color: #ff0000;&quot;&gt;[1]&lt;/span&gt;, &lt;span style=&quot;color: #ff6600;&quot;&gt;[2]&lt;/span&gt;에 해당하지 않으면서 그 단위길이당 중량이 70N/m 미만이면 내진검토를 생략할 수 있는데, 여기에 더해서 배연설비가 아닌 덕트는 단면적이 0.6㎡ 미만이면서 무게가 300N/m(≒30.6kg/m) 이하이고 구조물에 튼튼히 부착된 경우에는 내진검토를 생략할 수 있습니다.&lt;/span&gt;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;font-family: 'Noto Serif KR';&quot;&gt;설비배관도 &lt;span style=&quot;color: #333333; text-align: start;&quot;&gt;&amp;nbsp;&lt;/span&gt;&lt;span style=&quot;color: #ff0000;&quot;&gt;[1]&lt;/span&gt;&lt;span style=&quot;color: #333333; text-align: start;&quot;&gt;,&amp;nbsp;&lt;/span&gt;&lt;span style=&quot;color: #ff6600;&quot;&gt;[2]&lt;/span&gt; 에 해당하지 않으면서 구조물에 밀착하여 튼튼하게 부착된 경우라면 덕트의 내진검토 생략 조건을 준용할 수 있다고 판단됩니다. &lt;/span&gt;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;font-family: 'Noto Serif KR';&quot;&gt; 여기서 &amp;lsquo;튼튼히 부착&amp;rsquo;이란, 덕트를 구조체에 밀착시켜 앵커로 고정하는 것이며, 이때 앵커의 인발 및 전단 저항강도는 각각 앵커가 부담하는 자중의 1.4배 이상이면 충분하며(KDS 41 17 00, 18.4.1(2)①준용판단), 항복강도 500MPa 이상의 앵커를 사용하는 경우에는 비연성앵커로 간주하여 초과강도계수를 반영해 1.4의 2배를 적용하여 자중의 2.8배 이상 인발저항강도와 전단저항강도를 갖추었는지 시험성적서 또는 현장실험으로 확인하면 충분하다는 의견입니다.&lt;/span&gt;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;font-family: 'Noto Serif KR';&quot;&gt;&lt;span style=&quot;color: #800080;&quot;&gt;[5]&lt;/span&gt;&lt;span style=&quot;color: #ff0000;&quot;&gt; &lt;/span&gt;: 벽체설치형 기계설비 중에서, &lt;u&gt;생활공간이나 피난경로 상에 배치&lt;/u&gt;&lt;u&gt;되는 경우에는 탈락하여 전도되거나&lt;/u&gt;&lt;u&gt; &lt;/u&gt;&lt;u&gt;추락하면 인명안전을 위협할 수 있으므로 내진검토 대상&lt;/u&gt;입니다. 중량이 450N 이하의 장비를 내력벽면 또는 기둥에 설치하는 경우 직경 8㎜ 이상의 고정용 볼트 4개 이상으로 고정하면 내진검토를 생략할 수 있습니다. 이때 고정되는 벽체는 구조체를 기본으로 하고, 조적벽체인 경우에는 그 벽체가 내진검토를 통해 내진 보강되는 조건에서 고정할 수 있으며, 건식벽체인 경우에는 벽체를 구성하는 요소들과 분리된 별도 시스템의 지지대를 설치하여야 합니다.&lt;/span&gt;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;font-family: 'Noto Serif KR';&quot;&gt;금번 제정된 KDS 31 70 20 「기계설비 내진」은 기계설비의 내진설계는 KDS 41 17 00의 18.1.3.1의 설계절차에 따라 내진설계책임구조기술자(건축구조기술사)가 내진설계를 수행하거나, 기계설비 설계자가 기계설비분야 내진설계책임기술자(건축기계설비기술사)와 협력하여 내진설계를 진행하고, 설계계산서 혹은 시험성적서를 근거로 작성된 기계설비 내진설계도서는 건축기계설비기술사에 의해 검토된 후 건축구조기술사에게 제출하도록 규정하고 있습니다. &lt;span style=&quot;letter-spacing: 0px;&quot;&gt;즉 기계설비의 내진설계&lt;/span&gt;&lt;span style=&quot;letter-spacing: 0px;&quot;&gt;&amp;middot;&lt;/span&gt;&lt;span style=&quot;letter-spacing: 0px;&quot;&gt;검토의 수행 주체는 건축구조기술사&lt;/span&gt;&lt;span style=&quot;letter-spacing: 0px;&quot;&gt; &lt;/span&gt;&lt;span style=&quot;letter-spacing: 0px;&quot;&gt;또는 건축기계설비기술사입니다&lt;/span&gt;&lt;span style=&quot;letter-spacing: 0px;&quot;&gt;.&lt;/span&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;color: #333333; text-align: start;&quot; data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;table style=&quot;border-collapse: collapse; width: 100%;&quot; border=&quot;1&quot; data-ke-align=&quot;alignLeft&quot;&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style=&quot;width: 100%;&quot;&gt;&lt;span style=&quot;color: #9d9d9d;&quot;&gt;개인이라면 누구라도 자유롭게 사용하거나 인터넷 등에 제한 없이 공유할 수 있고, 정부, 지자체, 공공기관 ,학교 및 회사 등에서 교육용으로 사용하고 공유할 수 있습니다. 공유시에는 출처를 표기하여야 합니다. 다만 회사가 영업을 위한 홍보자료로 사용하기 위하여 일부 내용만 인용하거나 일부 그림을 사용하는 것은 거부합니다. 그리고 이 책자의 내용을 전부 또는 일부를 편집 또는 가공하여 금전적 이익을 취하는 것도 거부합니다. 이 내용을 현장 실무판단의 참고자료로 유용하게 사용하시길 바랍니다. 다만, 건설현장에서 책임구조기술자로서의 구조적 의견인 것으로 상대방을 오인시킬 의도로 작성된 문서 등에 첨부하거나 근거로 삼을 수 없고, 이해 당사자 간의 분쟁 또는 소송 등에서 다툼의 기준이나 근거로 삼을 수 없습니다.&lt;/span&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p style=&quot;color: #333333; text-align: start;&quot; data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p style=&quot;color: #333333; text-align: start;&quot; data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;font-family: 'Noto Sans Light'; color: #333333; text-align: start;&quot;&gt;제공 :&lt;span&gt;&amp;nbsp;&lt;/span&gt;&lt;/span&gt;&lt;a style=&quot;font-family: 'Noto Sans Light'; color: #0070d1; text-align: start;&quot; href=&quot;http://www.corest.co.kr&quot;&gt;&lt;span style=&quot;font-family: 'Noto Sans Demilight', 'Noto Sans KR';&quot;&gt;코어건축구조기술사사무소&lt;/span&gt;&lt;/a&gt;&lt;/p&gt;</description>
      <category>구조상식</category>
      <category>건축기계설비기술사</category>
      <category>기계비구조요소</category>
      <category>비구조</category>
      <category>비구조요소</category>
      <author>BMTARS</author>
      <guid isPermaLink="true">https://bmtars.tistory.com/312</guid>
      <comments>https://bmtars.tistory.com/312#entry312comment</comments>
      <pubDate>Thu, 21 May 2026 00:24:01 +0900</pubDate>
    </item>
    <item>
      <title>비구조요소 #F22-전기 비구조요소 중 내진설계 대상은?</title>
      <link>https://bmtars.tistory.com/311</link>
      <description>&lt;p&gt;&lt;figure class=&quot;imageblock alignCenter&quot; data-ke-mobileStyle=&quot;widthOrigin&quot; data-filename=&quot;blob&quot; data-origin-width=&quot;2122&quot; data-origin-height=&quot;3000&quot;&gt;&lt;span data-url=&quot;https://blog.kakaocdn.net/dn/bEKhuj/dJMcaiQUmJ7/yjGhFn0ymv3Ycl0KszlzjK/img.png&quot; data-phocus=&quot;https://blog.kakaocdn.net/dn/bEKhuj/dJMcaiQUmJ7/yjGhFn0ymv3Ycl0KszlzjK/img.png&quot;&gt;&lt;img src=&quot;https://blog.kakaocdn.net/dn/bEKhuj/dJMcaiQUmJ7/yjGhFn0ymv3Ycl0KszlzjK/img.png&quot; srcset=&quot;https://img1.daumcdn.net/thumb/R1280x0/?scode=mtistory2&amp;fname=https%3A%2F%2Fblog.kakaocdn.net%2Fdn%2FbEKhuj%2FdJMcaiQUmJ7%2FyjGhFn0ymv3Ycl0KszlzjK%2Fimg.png&quot; onerror=&quot;this.onerror=null; this.src='//t1.daumcdn.net/tistory_admin/static/images/no-image-v1.png'; this.srcset='//t1.daumcdn.net/tistory_admin/static/images/no-image-v1.png';&quot; loading=&quot;lazy&quot; width=&quot;2122&quot; height=&quot;3000&quot; data-filename=&quot;blob&quot; data-origin-width=&quot;2122&quot; data-origin-height=&quot;3000&quot;/&gt;&lt;/span&gt;&lt;/figure&gt;
&lt;figure class=&quot;imageblock alignCenter&quot; data-ke-mobileStyle=&quot;widthOrigin&quot; data-filename=&quot;blob&quot; data-origin-width=&quot;2122&quot; data-origin-height=&quot;3000&quot;&gt;&lt;span data-url=&quot;https://blog.kakaocdn.net/dn/eqv7wE/dJMcaiQUmM6/ALRdcKbQimvOKx0Qq17g91/img.png&quot; data-phocus=&quot;https://blog.kakaocdn.net/dn/eqv7wE/dJMcaiQUmM6/ALRdcKbQimvOKx0Qq17g91/img.png&quot;&gt;&lt;img src=&quot;https://blog.kakaocdn.net/dn/eqv7wE/dJMcaiQUmM6/ALRdcKbQimvOKx0Qq17g91/img.png&quot; srcset=&quot;https://img1.daumcdn.net/thumb/R1280x0/?scode=mtistory2&amp;fname=https%3A%2F%2Fblog.kakaocdn.net%2Fdn%2Feqv7wE%2FdJMcaiQUmM6%2FALRdcKbQimvOKx0Qq17g91%2Fimg.png&quot; onerror=&quot;this.onerror=null; this.src='//t1.daumcdn.net/tistory_admin/static/images/no-image-v1.png'; this.srcset='//t1.daumcdn.net/tistory_admin/static/images/no-image-v1.png';&quot; loading=&quot;lazy&quot; width=&quot;2122&quot; height=&quot;3000&quot; data-filename=&quot;blob&quot; data-origin-width=&quot;2122&quot; data-origin-height=&quot;3000&quot;/&gt;&lt;/span&gt;&lt;/figure&gt;
&lt;figure class=&quot;imageblock alignCenter&quot; data-ke-mobileStyle=&quot;widthOrigin&quot; data-filename=&quot;blob&quot; data-origin-width=&quot;2122&quot; data-origin-height=&quot;3000&quot;&gt;&lt;span data-url=&quot;https://blog.kakaocdn.net/dn/b4H3nq/dJMcag6EoaW/8cAKUgbKZhh3n6FBThsaLK/img.png&quot; data-phocus=&quot;https://blog.kakaocdn.net/dn/b4H3nq/dJMcag6EoaW/8cAKUgbKZhh3n6FBThsaLK/img.png&quot;&gt;&lt;img src=&quot;https://blog.kakaocdn.net/dn/b4H3nq/dJMcag6EoaW/8cAKUgbKZhh3n6FBThsaLK/img.png&quot; srcset=&quot;https://img1.daumcdn.net/thumb/R1280x0/?scode=mtistory2&amp;fname=https%3A%2F%2Fblog.kakaocdn.net%2Fdn%2Fb4H3nq%2FdJMcag6EoaW%2F8cAKUgbKZhh3n6FBThsaLK%2Fimg.png&quot; onerror=&quot;this.onerror=null; this.src='//t1.daumcdn.net/tistory_admin/static/images/no-image-v1.png'; this.srcset='//t1.daumcdn.net/tistory_admin/static/images/no-image-v1.png';&quot; loading=&quot;lazy&quot; width=&quot;2122&quot; height=&quot;3000&quot; data-filename=&quot;blob&quot; data-origin-width=&quot;2122&quot; data-origin-height=&quot;3000&quot;/&gt;&lt;/span&gt;&lt;/figure&gt;
&lt;figure class=&quot;imageblock alignCenter&quot; data-ke-mobileStyle=&quot;widthOrigin&quot; data-filename=&quot;blob&quot; data-origin-width=&quot;2122&quot; data-origin-height=&quot;3000&quot;&gt;&lt;span data-url=&quot;https://blog.kakaocdn.net/dn/ba7Bko/dJMcadWmKO8/BwACt6cNsIhhAeamTCJ5P0/img.png&quot; data-phocus=&quot;https://blog.kakaocdn.net/dn/ba7Bko/dJMcadWmKO8/BwACt6cNsIhhAeamTCJ5P0/img.png&quot;&gt;&lt;img src=&quot;https://blog.kakaocdn.net/dn/ba7Bko/dJMcadWmKO8/BwACt6cNsIhhAeamTCJ5P0/img.png&quot; srcset=&quot;https://img1.daumcdn.net/thumb/R1280x0/?scode=mtistory2&amp;fname=https%3A%2F%2Fblog.kakaocdn.net%2Fdn%2Fba7Bko%2FdJMcadWmKO8%2FBwACt6cNsIhhAeamTCJ5P0%2Fimg.png&quot; onerror=&quot;this.onerror=null; this.src='//t1.daumcdn.net/tistory_admin/static/images/no-image-v1.png'; this.srcset='//t1.daumcdn.net/tistory_admin/static/images/no-image-v1.png';&quot; loading=&quot;lazy&quot; width=&quot;2122&quot; height=&quot;3000&quot; data-filename=&quot;blob&quot; data-origin-width=&quot;2122&quot; data-origin-height=&quot;3000&quot;/&gt;&lt;/span&gt;&lt;/figure&gt;
&lt;/p&gt;
&lt;p style=&quot;color: #333333; text-align: start;&quot; data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;font-family: 'Noto Serif KR';&quot;&gt;2026년 2월 23일, KDS 32 17 00 「건축물 전기설비 내진 설계기준」이 제정되었습니다. 이 기준의 제정을 계기로 전기 비구조요소의 내진설계 대상을 안내합니다.&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;color: #333333; text-align: start;&quot; data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p style=&quot;color: #333333; text-align: start;&quot; data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;font-family: 'Noto Serif KR';&quot;&gt;&lt;span style=&quot;color: #ff0000;&quot;&gt;[1]&lt;/span&gt;&lt;span style=&quot;color: #ff0000;&quot;&gt; &lt;/span&gt;: 소방부하 관련 전기설비, 즉 소방전기는 인명안전과 직결되므로 필수 검토 대상입니다. &lt;/span&gt;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;font-family: 'Noto Serif KR';&quot;&gt; 비상부하 관련 전기설비(비상발전기&amp;middot;UPS 등) 중 비상부하에 &amp;lsquo;화재 시 부하&amp;rsquo;용량이 반영된 경우는 소방부하(&lt;span style=&quot;color: #ff0000;&quot;&gt;[1]&lt;/span&gt;)에 속하고, 제연설비&amp;middot;승강기에 부하용량이 반영된 경우는 인명안전을 위한 것이므로 &lt;span style=&quot;color: #ff0000; text-align: start;&quot;&gt;[1]&lt;/span&gt; 에 속한다고 볼 수 있으며, 비상조명등&amp;middot;유도등에 부하용량이 반영된 경우는 &lt;span style=&quot;color: #ff6600;&quot;&gt;[2]&lt;/span&gt;에 속하므로 역시 필수 검토 대상입니다.&lt;/span&gt;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;font-family: 'Noto Serif KR';&quot;&gt;&lt;span style=&quot;color: #ff6600;&quot;&gt;[2]&lt;/span&gt;&lt;span style=&quot;color: #ff0000;&quot;&gt; &lt;/span&gt;: 피난경로상의 비상유도등 자체는 정착부에 대한 검토를 진행(&lt;span style=&quot;background-color: #b900b9; color: #ffffff;&quot;&gt; &lt;/span&gt;&lt;span style=&quot;background-color: #b900b9; color: #ffffff;&quot;&gt;F15 &lt;/span&gt;참조)합니다. 천정형 유도등이 팬던트 방식으로 수직 노출된 전선관에 의해 매달리는 경우, 지진 시 과도한 흔들림이 발생할 수 있고, 과도한 흔들림이 발생하면 전선관 내부 배선이 단락되거나 전선관이 변형&amp;middot;파괴될 수 있으므로 내진검토가 필요합니다.&lt;/span&gt;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;font-family: 'Noto Serif KR';&quot;&gt;&lt;span style=&quot;color: #ff0000;&quot;&gt;[1] &lt;/span&gt;또는 &lt;span style=&quot;color: #ff6600;&quot;&gt;[2]&lt;/span&gt;에 속하지 않지만 전도 또는 추락하면 &lt;span style=&quot;color: #ff0000;&quot;&gt;[1] &lt;/span&gt;또는 &lt;span style=&quot;color: #ff6600;&quot;&gt;[2]&lt;/span&gt;의 설비에 손상을 줄 수 있는 위치에 설치되는 비구조요소라면 내진검토 대상입니다.&lt;/span&gt;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;font-family: 'Noto Serif KR';&quot;&gt;&lt;span style=&quot;color: #008000;&quot;&gt;[3]&lt;/span&gt;&lt;span style=&quot;color: #ff0000;&quot;&gt; &lt;/span&gt;: 내진특등급 건축물의 전기설비 중에서 아래 두 가지 중에 속하는 전기 비구조요소가 해당됩니다. &lt;/span&gt;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;font-family: 'Noto Serif KR';&quot;&gt; ① 중요한 기능을 갖는 전기설비로서 지속적인 기능수행이 요구되는 전기 비구조요소&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;text-align: left;&quot; data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;font-family: 'Noto Serif KR';&quot;&gt; ② 그 자체는 중요하지 않지만, 파괴되어 추락 또는 전도되면 중요한 장치를 손상시켜 시설물의 지속적인 가동에 지장을 줄 수 있는 위치에 설치되는 전기 비구조요소&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;text-align: left;&quot; data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;font-family: 'Noto Serif KR';&quot;&gt; 다양한 전기 비구조요소 중에서 상기에 해당하는 내진설계&amp;middot;검토 대상을 결정하는 것은 건축주(발주처/사용주체)와 건설전문가(감리자/시공자)가 함께 협의하여 결정하는 것이 바람직합니다. 지진 시에도 파괴되지 않고 지진 후에도 가동되어야 하는 핵심 설비가 어떤 것인지는 시설물의 운영에 관한 계획&amp;middot;방침&amp;middot;경험 등을 보유한 운영주체인 건축주(발주처/사용주체)만이 특정할 수 있습니다. 또한 건축주가 특정한 핵심 설비에 대해서 다양한 공종 및 계통설비 중 손상을 일으킬 수 있는 비구조요소는 공사계획을 파악한 건설전문가가 추려내 특정할 수 있습니다. 상호 긴밀한 협력과 논의를 통해서만이 합리적이고 효율적인 결정, 즉 불필요한 예산낭비를 방지하면서 기능수행 능력을 안정적으로 확보할 수 있는 결정에 도달할 수 있습니다.&lt;/span&gt;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;font-family: 'Noto Serif KR';&quot;&gt; 내진특등급이 아닌 시설물이더라도 은행의 전산&amp;middot;서버장치와 같이 지진 후에도 지속 가동되어야 한다고 건축주가 판단한다면 기준(KDS 41 17 00) 18.1.1의 (3)항에 따라 건축주는 시공자와 협의하여 자율적으로 검토 진행을 결정할 수 있습니다.&lt;/span&gt;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;font-family: 'Noto Serif KR';&quot;&gt;&lt;span style=&quot;color: #0000ff;&quot;&gt;[4]&lt;/span&gt;&lt;span style=&quot;color: #ff0000;&quot;&gt; &lt;/span&gt;: &lt;span style=&quot;color: #ff0000;&quot;&gt;[1]&lt;/span&gt;, &lt;span style=&quot;color: #ff6600;&quot;&gt;[2]&lt;/span&gt;, &lt;span style=&quot;color: #008000;&quot;&gt;[3]&lt;/span&gt;에 해당하지 않는 바닥설치형 전기설비 배전반&amp;middot;분전반&amp;middot;제어반&amp;middot;자가발전설비&amp;middot;배터리랙 등은 정착부가 튼튼하지 않으면 지진 시 전도될 수 있습니다. &lt;u&gt;전도 시 사람을 덮칠 수 있는 위치에 설치될 경우에는&lt;/u&gt;&lt;u&gt; &lt;/u&gt;&lt;u&gt;인명안전을 위협하는 요소로서&lt;/u&gt;&lt;u&gt; &lt;/u&gt;&lt;u&gt;내진검토 대상&lt;/u&gt;입니다. 바닥설치형 전기설비가 전기실/옥상휀스구역 등 출입통제되는 곳에 설치되면 지진 시 전도되더라도 인명안전에 위협이 될 가능성은 낮습니다. 내진검토보다 더욱 근본적이고 효과적인 조치는 관리적 측면에 있다고 여겨집니다. 접근 통제구역 설정&amp;middot;관리, 관리자 재난안전 행동수칙 수립&amp;middot;관리, 2차 전도될 수 있는 휀스를 장비높이 이상 적정하게 이격하여 설치하는 것 등등 세심한 관리적 예방조치가 더욱 중요합니다. 그러나 이러한 관리적 예방조치를 할 수 없거나, 하더라도 인명안전의 위협이 있다고 우려되면 내진검토를 통해 정착부가 충분히 안전한지 확인하고 보강할 수 있습니다. 중량 1,800N(≒183kg)를 초과하는 바닥설치형 전기설비는 내진검토를 통해 정착부의 안전성을 검토합니다. 중량 1,800N 이하면서 450N(≒45.9kg)를 초과하는 장비는 제품공급 제조사가 인증하는 방법으로 설치 시 정착부에 대한 내진검토를 생략할 수 있습니다. 중량 450N 이하의 장비를 내력벽면 또는 기둥에 설치하는 경우 직경 8㎜ 이상의 고정용 볼트 4개 이상으로 고정(「소방시설의 내진설계 기준」, 제14조제1항)하면 그 정착부에 대한 내진검토를 생략할 수 있습니다.&lt;/span&gt;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;font-family: 'Noto Serif KR';&quot;&gt;&lt;span style=&quot;color: #800080;&quot;&gt;[5]&lt;/span&gt;&lt;span style=&quot;color: #ff0000;&quot;&gt; &lt;/span&gt;: 매달리는 전기설비 중에서 무거운 것은 지진 시 과도하게 흔들리면 행거볼트가 파단되어 추락할 수 있는데, 이때 매달리는 &lt;u&gt;무거운 전기설비가 생활공간이나 피난경로 상에 배치된 경우에는 인명안전을 위협하므로 내진검토 대상&lt;/u&gt;입니다. 이때 무거운 전기설비라 함은 장비(기기&amp;middot;장치)가 중량 100N(≒10.2kg) 초과, 배선설비(전선로)는 단위길이당 중량이 70N/m(≒7.1kg/m)를 초과하는 경우입니다.&amp;nbsp; &lt;/span&gt;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;font-family: 'Noto Serif KR';&quot;&gt; 매달리는 장비로서 천장에 부착되거나 전산볼트 등 행거에 매달리는 전등(조명기구)&amp;middot;전열&amp;middot;통신&amp;middot;방송(TV&amp;middot;빔프로젝트&amp;middot;스피커 등) 등의 비구조요소가 &lt;span style=&quot;color: #008000;&quot;&gt;[3]&lt;/span&gt;에 해당하지 않으면서 그 중량이 100N이하라면 내진검토를 생략할 수 있습니다. (Ip=1.5인 소방부하&amp;middot;비상부하 관련 장비는 제외)&amp;nbsp; 매달리는 배선설비로서 천장에 부착되거나 전산볼트 등 행거에 매달리는 케이블트레이&amp;middot;버스덕트&amp;middot;전선관 등의 비구조요소가 &lt;span style=&quot;color: #008000;&quot;&gt;[3]&lt;/span&gt;에 해당하지 않으면서 그 단위길이당 중량이 70N/m이하라면 내진검토를 생략할 수 있는데, 다만 여기에 전선관(레이스웨이&amp;middot;노출전선관 등의 도관)은 크기가 60㎜ 미만이어야 하는 추가 조건도 충족해야 합니다.&lt;/span&gt;&lt;span style=&quot;font-family: 'Noto Serif KR';&quot;&gt;&lt;/span&gt;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;font-family: 'Noto Serif KR';&quot;&gt; 무겁다고 무조건 내진검토 대상이 되는 것이 아니라, 소방&amp;middot;비상&amp;middot;피난&amp;middot;기능수행&amp;middot;인명안전을 위협하지 않으면 검토대상이 아닙니다. 그러나 예를 들면 일반적인 케이블트레이가 소방&amp;middot;비상&amp;middot;기능수행과 무관하더라도 생활공간이나 피난경로 상에 설치되면 인명안전을 위협하는 요소가 됩니다.&lt;/span&gt;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;font-family: 'Noto Serif KR';&quot;&gt;통신&amp;middot;방송&amp;middot;자동제어설비 등은 별도의 내진설계기준이 아직 없으므로 상기 전기 비구조요소의 기준을 준용하여 참조하시기 바랍니다.&lt;/span&gt;&lt;/p&gt;
&lt;p style=&quot;color: #333333; text-align: start;&quot; data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;table style=&quot;border-collapse: collapse; width: 100%;&quot; border=&quot;1&quot; data-ke-align=&quot;alignLeft&quot;&gt;
&lt;tbody&gt;
&lt;tr&gt;
&lt;td style=&quot;width: 100%;&quot;&gt;&lt;span style=&quot;color: #9d9d9d;&quot;&gt;개인이라면 누구라도 자유롭게 사용하거나 인터넷 등에 제한 없이 공유할 수 있고, 정부, 지자체, 공공기관 ,학교 및 회사 등에서 교육용으로 사용하고 공유할 수 있습니다. 공유시에는 출처를 표기하여야 합니다. 다만 회사가 영업을 위한 홍보자료로 사용하기 위하여 일부 내용만 인용하거나 일부 그림을 사용하는 것은 거부합니다. 그리고 이 책자의 내용을 전부 또는 일부를 편집 또는 가공하여 금전적 이익을 취하는 것도 거부합니다. 이 내용을 현장 실무판단의 참고자료로 유용하게 사용하시길 바랍니다. 다만, 건설현장에서 책임구조기술자로서의 구조적 의견인 것으로 상대방을 오인시킬 의도로 작성된 문서 등에 첨부하거나 근거로 삼을 수 없고, 이해 당사자 간의 분쟁 또는 소송 등에서 다툼의 기준이나 근거로 삼을 수 없습니다.&lt;/span&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;/tbody&gt;
&lt;/table&gt;
&lt;p style=&quot;color: #333333; text-align: start;&quot; data-ke-size=&quot;size16&quot;&gt;&amp;nbsp;&lt;/p&gt;
&lt;p style=&quot;color: #333333; text-align: start;&quot; data-ke-size=&quot;size16&quot;&gt;&lt;span style=&quot;font-family: 'Noto Sans Light'; color: #333333; text-align: start;&quot;&gt;제공 :&lt;span&gt;&amp;nbsp;&lt;/span&gt;&lt;/span&gt;&lt;a style=&quot;font-family: 'Noto Sans Light'; color: #0070d1; text-align: start;&quot; href=&quot;http://www.corest.co.kr&quot;&gt;&lt;span style=&quot;font-family: 'Noto Sans Demilight', 'Noto Sans KR';&quot;&gt;코어건축구조기술사사무소&lt;/span&gt;&lt;/a&gt;&lt;/p&gt;</description>
      <category>구조상식</category>
      <category>비구조</category>
      <category>비구조요소</category>
      <category>전기비구조요소</category>
      <author>BMTARS</author>
      <guid isPermaLink="true">https://bmtars.tistory.com/311</guid>
      <comments>https://bmtars.tistory.com/311#entry311comment</comments>
      <pubDate>Thu, 21 May 2026 00:16:14 +0900</pubDate>
    </item>
  </channel>
</rss>